Publications


BMIT Peer-Reviewed Article Entries

2021 

  • Andronowski, Janna M.; Cole, Mary E.; Hieronymus, Tobin L.; Davis, Reed A.; Usher, Logan R. et al. (2021). Intraskeletal consistency in patterns of vascularity within bat limb bones. Anatomical Record . 10.1002/ar.24694.
  • Balakrishnan, Manojkumar; Shrestha, Pranay; Lee, ChungHyuk; Ge, Nan; Fahy, Kieran F. et al. (2021). Degradation Characteristics of Electrospun Gas Diffusion Layers with Custom Pore Structures for Polymer Electrolyte Membrane Fuel Cells. ACS applied materials & interfaces . 10.1021/acsami.0c15324.
  • Ehsani, Masoume; Zhu, Ning; Doan, Huu; Lohi, Ali; Abdelrasoul, Amira et al. (2021). In-situ synchrotron X-ray imaging of ultrasound (US)-generated bubbles: Influence of US frequency on microbubble cavitation for membrane fouling remediation. Ultrasonics Sonochemistry 77, 105697. 10.1016/j.ultsonch.2021.105697.
  • Fu, Xiaogang; Gao, Rui; Jiang, Gaopeng; Li, Matthew; Li, Shuang et al. (2021). Evolution of atomic-scale dispersion of FeNx in hierarchically porous 3D air electrode to boost the interfacial electrocatalysis of oxygen reduction in PEMFC. Nano Energy 83, 105734. 10.1016/j.nanoen.2020.105734.
  • Grochulski, Pawel; Labiuk, Shaunivan (2021). Review of health research at the Canadian Light Source. Nuclear Instruments and Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 499, 70-76. 10.1016/j.nimb.2021.05.003.
  • Guldiken, Burcu; Stobbs, Jarvis; Nickerson, Michael (2021). Heat induced gelation of pulse protein networks. Food Chemistry 350, 129158. 10.1016/j.foodchem.2021.129158.
  • Krause, Kevin; Lee, ChungHyuk; Lee, Jason K.; Fahy, Kieran F.; Shafaque, Hisan W. et al. (2021). Unstable Cathode Potential in Alkaline Flow Cells for CO2 Electroreduction Driven by Gas Evolution. ACS Sustainable Chemistry and Engineering . 10.1021/acssuschemeng.0c08993.
  • Köble, Kerstin; Eifert, László; Bevilacqua, Nico; Fahy, Kieran F.; Bazylak, Aimy et al. (2021). Synchrotron X-Ray radiography of vanadium redox flow batteries – Time and spatial resolved electrolyte flow in porous carbon electrodes. Journal of Power Sources 492, 229660. 10.1016/j.jpowsour.2021.229660.
  • Li, Chen; Zhang, Yuzhou; Zhu, Ning; Emady, Heather N.; Zhang, Lifeng et al. (2021). Experimental investigation of wet pharmaceutical granulation using in-situ synchrotron X-ray imaging. Powder Technology 378(Part A) , 65-75. 10.1016/j.powtec.2020.09.063.
  • Li, Hao; Helpard, Luke; Ekeroot, Jonas; Rohani, Seyed Alireza; Zhu, Ning et al. (2021). Three-dimensional tonotopic mapping of the human cochlea based on synchrotron radiation phase-contrast imaging. Scientific Reports 11(1) , Article No.: 4437. 10.1038/s41598-021-83225-w.
  • Li, Xiaoling; Zhang, Ke; Chang, Liping; Wang, Hui (2021). Review of researches on H2S splitting cycle for hydrogen production via low-temperature route. Chemical Engineering Science: X 11, 100107. 10.1016/j.cesx.2021.100107.
  • MacIver, Michael R.; Hamza, Hassan; Pawlik, Marek (2021). Effect of suspension conductivity and fines concentration on coarse particle settling in oil sands tailings. Canadian Journal of Chemical Engineering . 10.1002/cjce.23935.
  • Mollahosseini, Arash; Min Lee, Kyu; Abdelrasoul, Amira; Doan, Huu; Zhu, Ning et al. (2021). Innovative in situ investigations using synchrotron‐based micro tomography and molecular dynamics simulation for fouling assessment in ceramic membranes for dairy and food industry. International Journal of Applied Ceramic Technology . 10.1111/ijac.13824.
  • Mushtaha, Farah N.; Kuehn, Tristan K.; El‐Deeb, Omar; Rohani, Seyed A.; Helpard, Luke W. et al. (2021). Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI. Magnetic Resonance in Medicine . 10.1002/mrm.28886.
  • Ning, Liqun; Zhu, Ning; Smith, An; Rajaram, Ajay; Hou, Huishu et al. (2021). Noninvasive Three-Dimensional In Situ and In Vivo Characterization of Bioprinted Hydrogel Scaffolds Using the X-ray Propagation-Based Imaging Technique. ACS applied materials & interfaces . 10.1021/acsami.1c02297.
  • Rahman, K.M.M.; Qin, W.; Szpunar, J.A.; Kozinski, J.; Song, M. et al. (2021). New insight into the role of inclusions in hydrogen-induced degradation of fracture toughness: three-dimensional imaging and modeling. The Philosophical Magazine A Journal of Theoretical Experimental and Applied Physics , 1-21. 10.1080/14786435.2021.1876267.
  • Sarker, Tumpa Rani; Azargohar, Ramin; Dalai, Ajay K.; Meda, Venkatesh (2021). Characteristics of torrefied fuel pellets obtained from co-pelletization of agriculture residues with pyrolysis oil. Biomass and Bioenergy 150, 106139. 10.1016/j.biombioe.2021.106139.
  • Shafaque, Hisan W.; Lee, Jason K.; Krause, Kevin; Lee, ChungHyuk; Fahy, Kieran F. et al. (2021). Temperature enhances the ohmic and mass transport behaviour in membrane electrode assembly carbon dioxide electrolyzers. Energy Conversion and Management 243, 114302. 10.1016/j.enconman.2021.114302.
  • Westphalen, Heloisa; Abdelrasoul, Amira; Shoker, Ahmed; Zhu, Ning (2021). Assessment of Hemodialysis Clinical Practices using Polyaryl Ether Sulfone-Polyvinylpyrrolidone (PAES: PVP) Clinical Membrane: Modeling of in vitro Fibrinogen Adsorption, in situ Synchrotron-based Imaging, and Clinical Inflammatory Biomarkers Investigations. Separation and Purification Technology 259, 118136. 10.1016/j.seppur.2020.118136.
  • Zhang, Yuzhou; Hirpara, Viral; Patel, Virat; Li, Chen; Anderson, Ryan et al. (2021). Imaging of desaturation of the frozen gas diffusion layers by synchrotron X-ray radiography. International Journal of Hydrogen Energy . 10.1016/j.ijhydene.2021.02.197.

2020 

  • Abdelrasoul, Amira; Doan, Huu; Lohi, Ali; Zhu, Ning (2020). Synchrotron based Micro Tomography (SR-µCT), Experimental, and Computational Studies to Investigate the Influences of Cross Flow Air Injection in Ultrafiltration Process. Journal of Environmental Chemical Engineering , 104611. 10.1016/j.jece.2020.104611.
  • Adair, Keegan R.; Banis, Mohammad Norouzi; Zhao, Yang; Bond, Toby; Li, Ruying et al. (2020). Temperature‐Dependent Chemical and Physical Microstructure of Li Metal Anodes Revealed through Synchrotron‐Based Imaging Techniques. Advanced Materials 32(32) , 2002550. 10.1002/adma.202002550.
  • Andronowski, Janna M.; Cole, Mary E. (2020). Current and emerging histomorphometric and imaging techniques for assessing age‐at‐death and cortical bone quality. Wiley Interdisciplinary Reviews Forensic Science , e1399. 10.1002/wfs2.1399.
  • Andronowski, Janna M.; Davis, Reed A.; Holyoke, Caleb W. (2020). A Sectioning, Coring, and Image Processing Guide for High-Throughput Cortical Bone Sample Procurement and Analysis for Synchrotron Micro-CT. Journal of Visualized Experiments (160) , e61081. 10.3791/61081.
  • Ay, Birol; Parolia, Kushagra; Liddell, Robert S.; Qiu, Yusheng; Grasselli, Giovanni et al. (2020). Hyperglycemia compromises Rat Cortical Bone by Increasing Osteocyte Lacunar Density and Decreasing Vascular Canal Volume. Communications Biology 3(20) , 1-9. 10.1038/s42003-019-0747-1.
  • Balakrishnan, Manojkumar; Shrestha, Pranay; Ge, Nan; Lee, ChungHyuk; Fahy, Kieran F. et al. (2020). Designing Tailored Gas Diffusion Layers with Pore Size Gradients via Electrospinning for Polymer Electrolyte Membrane Fuel Cells. ACS Applied Energy Materials 3(3) , 2695-2707. 10.1021/acsaem.9b02371.
  • Bhagavathula, KB; Parcon, JS; Azar, A; Ouellet, S; Satapathy, S et al. (2020). Quasistatic response of a shear-thickening foam: Microstructure evolution and infrared thermography. Journal of Cellular Plastics , 0021955X2096398. 10.1177/0021955x20963989.
  • Cardenas, Daniel; Turyanskaya, Anna; Rauwolf, Mirjam; Panahifar, Arash; Cooper, David et al. (2020). Determining elemental strontium distribution in rat bones treated with strontium ranelate and strontium citrate using 2D micro‐XRF and 3D dual energy K‐edge subtraction synchrotron imaging. X-Ray Spectrometry 49(3) , 424-433. 10.1002/xrs.3127.
  • Chicilo, F; Hanson, A L; Geisler, F H; Belev, G; Edgar, A et al. (2020). Dose profiles and x-ray energy optimization for microbeam radiation therapy by high-dose, high resolution dosimetry using Sm-doped fluoroaluminate glass plates and Monte Carlo transport simulation. Physics in Medicine and Biology 65(7) , 075010. 10.1088/1361-6560/ab7361.
  • Chicilo, F; Okada, G; Belev, G; Chapman, D; Edgar, A et al. (2020). Instrumentation for high-dose, high-resolution dosimetry for microbeam radiation therapy using samarium-doped fluoroaluminate and fluorophosphate glass plates. Measurement Science and Technology (31) , 015201-1 - 015201-13. 10.1088/1361-6501/ab404e.
  • Eifert, László; Bevilacqua, Nico; Köble, Kerstin; Fahy, Kieran; Xiao, Liusheng et al. (2020). Synchrotron X-ray Radiography and Tomography of Vanadium Redox Flow Batteries - Cell Design, Electrolyte Flow Geometry, and Gas Bubble Formation. ChemSusChem 13, 3154 –3165. 10.1002/cssc.202000541.
  • Helpard, Luke; Li, Hao; Rask-Andersen, Helge; Ladak, Hanif M.; Agrawal, Sumit K. et al. (2020). Characterization of the human helicotrema: implications for cochlear duct length and frequency mapping. Journal of Otolaryngology - Head and Neck Surgery 49(2) . 10.1186/s40463-019-0398-8.
  • Hirpara, Viral; Patel, Virat; Zhang, Yuzhou; Anderson, Ryan; Zhu, Ning et al. (2020). Investigating the effect of operating temperature on dynamic behavior of droplets for proton exchange membrane fuel cells. International Journal of Hydrogen Energy 45(27) , 14145-14155. 10.1016/j.ijhydene.2020.03.128.
  • Kim, P. J.; Lee, CH.; Lee, J. K.; Fahy, K.F.; Bazylak, A. et al. (2020). In-Plane Transport in Water Electrolyzer Porous Transport Layers with Through Pores. Journal of the Electrochemical Society 167(12) , 124522. 10.1149/1945-7111/abb173.
  • Lee, CH.; Lee, J. K.; Zhao, B.; Fahy, K. F.; Bazylak, A. et al. (2020). Transient Gas Distribution in Porous Transport Layers of Polymer Electrolyte Membrane Electrolyzers. Journal of the Electrochemical Society 167(2) , 024508. 10.1149/1945-7111/ab68c8.
  • Lee, Jason K.; Lee, ChungHyuk; Fahy, Kieran F.; Kim, Pascal J.; Krause, Kevin et al. (2020). Accelerating bubble detachment in porous transport layers with patterned through pores. ACS Applied Energy Materials 3(10) , 9676–9684. 10.1021/acsaem.0c01239.
  • Li, Hao; Schart-Morén, Nadine; Rohani, Seyed Alireza; Ladak, Hanif M.; Rask-Andersen, Helge et al. (2020). Synchrotron Radiation-Based Reconstruction of the Human Spiral Ganglion. Ear and Hearing 41(1) , 173–181. 10.1097/aud.0000000000000738.
  • Lo, Calvin; Sano, Tomoko; Hogan, James D. (2020). Deformation mechanisms and evolution of mechanical properties in damaged advanced ceramics. Journal of the European Ceramic Society 40(8) , 3129-3139. 10.1016/j.jeurceramsoc.2020.02.058.
  • Loundagin, Lindsay L.; Haider, Ifaz T.; Cooper, David M.L.; Edwards, W. Brent (2020). Association between intracortical microarchitecture and the compressive fatigue life of human bone: A pilot study. Bone Reports 12, 100254. 10.1016/j.bonr.2020.100254.
  • Mei, Xueshuang; Glueckert, Rudolf; Schrott-Fischer, Annelies; Li, Hao; Ladak, Hanif M. et al. (2020). Vascular Supply of the Human Spiral Ganglion: Novel Three-Dimensional Analysis Using Synchrotron Phase-Contrast Imaging and Histology. Scientific Reports 10(1) , 5877. 10.1038/s41598-020-62653-0.
  • Ning, Liqun; Mehta, Riya; Cao, Cong; Theus, Andrea; Tomov, Martin et al. (2020). Embedded 3D Bioprinting of Gelatin Methacryloyl-Based Constructs with Highly Tunable Structural Fidelity. ACS applied materials & interfaces 12(40) , 44563–44577. 10.1021/acsami.0c15078.
  • Nordström, Charlotta Kämpfe; Li, Hao; Ladak, Hanif M.; Agrawal, Sumit; Rask-Andersen, Helge et al. (2020). A Micro-CT and Synchrotron Imaging Study of the Human Endolymphatic Duct with Special Reference to Endolymph Outflow and Meniere’s Disease. Scientific Reports 10(8295) . 10.1038/s41598-020-65110-0.
  • Qi, Peng; Samadi, Nazanin; Chapman, Dean (2020). X-ray Spectral Imaging Program: XSIP. Journal of Synchrotron Radiation 27(6) , 1734-1740. 10.1107/s1600577520010838.
  • ROHANI, S.A.; ALLEN, D.; GARE, B.; ZHU, N.; AGRAWAL, S. et al. (2020). High‐resolution imaging of the human incudostapedial joint using synchrotron‐radiation phase‐contrast imaging. Journal of Microscopy 277(2) , 61-70. 10.1111/jmi.12864.
  • Saadati, Shaghayegh; Westphalen, Heloisa; Eduok, Ubong; Abdelrasoul, Amira; Shoker, Ahmed et al. (2020). Biocompatibility enhancement of hemodialysis membranes using a novel zwitterionic copolymer: Experimental, in situ synchrotron imaging, molecular docking, and clinical inflammatory biomarkers investigations. Materials Science and Engineering C 117, 111301. 10.1016/j.msec.2020.111301.
  • Shrestha, P.; Lee, CH.; Fahy, K. F.; Balakrishnan, M.; Ge, N. et al. (2020). Formation of Liquid Water Pathways in PEM Fuel Cells: A 3-D Pore-Scale Perspective. Journal of the Electrochemical Society 167(5) , 054516. 10.1149/1945-7111/ab7a0b.
  • Sun, Xinyang; Scanlon, Martin G.; Guillermic, Reine-Marie; Belev, George S.; Webb, M. Adam et al. (2020). The effects of sodium reduction on the gas phase of bread doughs using synchrotron X-ray microtomography. Food Research International 130, 108919. 10.1016/j.foodres.2019.108919.
  • Ton, Ngoc; Goncin, Una; Panahifar, Arash; Chapman, Dean; Wiebe, Sheldon et al. (2020). Developing a Microbubble-based Contrast Agent for Synchrotron In-line Phase Contrast Imaging. IEEE Transactions on Biomedical Engineering . 10.1109/tbme.2020.3040079.
  • Wang, Qiong; Tang, Tengteng; Cooper, David; Eltit, Felipe; Fratzl, Peter et al. (2020). Globular structure of the hypermineralized tissue in human femoral neck. Journal of Structural Biology 212(2) , 107606. 10.1016/j.jsb.2020.107606.
  • Willick, Ian R.; Stobbs, Jarvis; Karunakaran, Chithra; Tanino, Karen K. (2020). Phenotyping Plant Cellular and Tissue Level Responses to Cold with Synchrotron-Based Fourier-Transform Infrared Spectroscopy and X-Ray Computed Tomography. Methods in Molecular Biology , 141-159. 10.1007/978-1-0716-0660-5_11.

2019 

  • Atake, Oghenevwogaga J.; Cooper, David M.L.; Eames, B. Frank (2019). Bone-like features in skate suggest a novel elasmobranch synapomorphy and deep homology of trabecular mineralization patterns. Acta Biomaterialia 84, 424-436. 10.1016/j.actbio.2018.11.047.
  • Azargohar, Ramin; Nanda, Sonil; Kang, Kang; Bond, Toby; Karunakaran, Chithra et al. (2019). Effects of bio-additives on the physicochemical properties and mechanical behavior of canola hull fuel pellets. Renewable Energy 132, 296-307. 10.1016/j.renene.2018.08.003.
  • Azargohar, Ramin; Soleimani, Majid; Nosran, Shivam; Bond, Toby; Karunakaran, Chithra et al. (2019). Thermo-physical characterization of torrefied fuel pellet from co-pelletization of canola hulls and meal. Industrial Crops and Products 128, 424-435. 10.1016/j.indcrop.2018.11.042.
  • BUKEJS, ANDRIS; ALEKSEEV, VITALII I.; COOPER, DAVID M.L.; KING, GAVIN A.; MCKELLAR, RYAN C. et al. (2019). A new fossil species of Pycnomerus Erichson (Coleoptera: Zopheridae) from Baltic amber, and a replacement name for a Recent North American congener. Zootaxa 4550(4) , 565. 10.11646/zootaxa.4550.4.6.
  • Battrell, Logan; Patel, Virat; Zhu, Ning; Zhang, Lifeng; Anderson, Ryan et al. (2019). Imaging of the desaturation of gas diffusion layers by synchrotron computed tomography. Journal of Power Sources 416, 155-162. 10.1016/j.jpowsour.2019.01.089.
  • Bevilacqua, Nico; Eifert, László; Banerjee, Rupak; Köble, Kerstin; Faragó, Tomáš et al. (2019). Visualization of electrolyte flow in vanadium redox flow batteries using synchrotron X-ray radiography and tomography – Impact of electrolyte species and electrode compression. Journal of Power Sources 439, 227071. 10.1016/j.jpowsour.2019.227071.
  • Brar, Gurcharn S.; Karunakaran, Chithra; Bond, Toby; Stobbs, Jarvis; Liu, Na et al. (2019). Showcasing the application of synchrotron-based X-ray computed tomography in host-pathogen interactions: The role of wheat rachilla and rachis nodes in Type-II resistance to Fusarium graminearum. Plant. Cell and Environment 42(2) , 509-526. 10.1111/pce.13431.
  • Dydula, Christopher; Belev, George; Johns, Paul C. (2019). Development and assessment of a multi-beam continuous-phantom-motion x-ray scatter projection imaging system. Review of Scientific Instruments 90(3) , 035104-1 - 035104-13. 10.1063/1.5043393.
  • Enghag, Sara; Strömbäck, Karin; Li, Hao; Rohani, Seyed Alireza; Ladak, Hanif M. et al. (2019). Incus Necrosis and Blood Supply. Otology and Neurotology 40(7) , e713–e722. 10.1097/mao.0000000000002292.
  • Ge, N.; Banerjee, R.; Muirhead, D.; Lee, J.; Liu, H. et al. (2019). Membrane dehydration with increasing current density at high inlet gas relative humidity in polymer electrolyte membrane fuel cells. Journal of Power Sources 422, 163-174. 10.1016/j.jpowsour.2019.03.001.
  • Ge, N.; Chevalier, S.; Muirhead, D.; Banerjee, R.; Lee, J. et al. (2019). Detecting cathode corrosion in polymer electrolyte membrane fuel cells in dead-ended anode mode via alternating current impedance. Journal of Power Sources 439, 227089. 10.1016/j.jpowsour.2019.227089.
  • Ge, N.; Shrestha, P.; Balakrishnan, M.; Ouellette, D.; Wong, A.K.C. et al. (2019). Resolving the gas diffusion layer substrate land and channel region contributions to the oxygen transport resistance of a partially-saturated substrate. Electrochimica Acta 328, 135001. 10.1016/j.electacta.2019.135001.
  • Izadifar, Zahra; Babyn, Paul; Chapman, Dean (2019). Ultrasound Cavitation/Microbubble Detection and Medical Applications. Journal of Medical and Biological Engineering 39(3) , 259–276. 10.1007/s40846-018-0391-0.
  • Lee, J.; Liu, H.; George, M.G.; Banerjee, R.; Ge, N. et al. (2019). Microporous layer to carbon fibre substrate interface impact on polymer electrolyte membrane fuel cell performance. Journal of Power Sources 422, 113-121. 10.1016/j.jpowsour.2019.02.099.
  • Li, Chen; Zhu, Ning; Emady, Heather N.; Zhang, Lifeng (2019). Synchrotron-based X-ray in-situ imaging techniques for advancing the understanding of pharmaceutical granulation. International Journal of Pharmaceutics 572, 118797. 10.1016/j.ijpharm.2019.118797.
  • Lo, Calvin; Sano, Tomoko; Hogan, James D. (2019). Microstructural and mechanical characterization of variability in porous advanced ceramics using X-ray computed tomography and digital image correlation. Materials Characterization 158, 109929. 10.1016/j.matchar.2019.109929.
  • Luan, Xiaojie; Tam, Julian S.; Belev, George; Jagadeeshan, Santosh; Murray, Brendan et al. (2019). Nebulized hypertonic saline triggers nervous system-mediated active liquid secretion in cystic fibrosis swine trachea. Scientific Reports 9(1) , 540. 10.1038/s41598-018-36695-4.
  • Mei, Xueshuang; Schart‐Morén, Nadine; Li, Hao; Ladak, Hanif M.; Agrawal, Sumit et al. (2019). Three‐dimensional imaging of the human internal acoustic canal and arachnoid cistern: a synchrotron study with clinical implications. Journal of Anatomy 234(3) , 316-326. 10.1111/joa.12926.
  • Mostafijur Rahman, K.M.; Mohtadi-Bonab, M.A.; Ouellet, Ryan; Szpunar, Jerzy; Zhu, Ning et al. (2019). Effect of electrochemical hydrogen charging on an API X70 pipeline steel with focus on characterization of inclusions. International Journal of Pressure Vessels and Piping 173, 147-155. 10.1016/j.ijpvp.2019.05.006.
  • Ning, Liqun; Zhu, Ning; Mohabatpour, Fatemeh; Sarker, M. D.; Schreyer, David J. et al. (2019). Bioprinting Schwann cell-laden scaffolds from low-viscosity hydrogel compositions. Journal of Materials Chemistry B 7(29) , 4538-4551. 10.1039/c9tb00669a.
  • Panahifar, Arash; Chapman, L. Dean; Weber, Lynn; Samadi, Nazanin; Cooper, David M. L. et al. (2019). Biodistribution of strontium and barium in the developing and mature skeleton of rats. Journal of Bone and Mineral Metabolism 37(3) , 385–398. 10.1007/s00774-018-0936-x.
  • Patel, Virat; Battrell, Logan; Anderson, Ryan; Zhu, Ning; Zhang, Lifeng et al. (2019). Investigating effect of different gas diffusion layers on water droplet characteristics for proton exchange membrane (PEM) fuel cells. International Journal of Hydrogen Energy 44(33) , 18340-18350. 10.1016/j.ijhydene.2019.05.111.
  • Qi, Peng; Samadi, Nazanin; Martinson, Mercedes; Ponomarenko, Olena; Bassey, Bassey et al. (2019). Wide field imaging energy dispersive X-ray absorption spectroscopy. Scientific Reports 9(1) , 17734 (1-14). 10.1038/s41598-019-54287-8.
  • ROHANI, S. ALIREZA; IYANIWURA, JOHN E.; ZHU, NING; AGRAWAL, SUMIT K.; LADAK, HANIF M. et al. (2019). Effects of object-to-detector distance and beam energy on synchrotron radiation phase-contrast imaging of implanted cochleae. Journal of Microscopy 273(2) , 127-134. 10.1111/jmi.12768.
  • Rahman, KM Mostafijur; Szpunar, Jerzy; Toroghinejad, Mohammad Reza; Belev, George (2019). Characterization of aluminum/alumina/TiC hybrid composites in 3D produced by anodizing and accumulating roll bonding process using synchrotron radiation tomography. Journal of Composite Materials 53(9) , 1215-1227. 10.1177/0021998318796177.
  • Samadi, Nazanin; Shi, Xianbo; Dallin, Les; Chapman, Dean (2019). A real-time phase-space beam emittance monitoring system. Journal of Synchrotron Radiation 26(4) , 1213-1219. 10.1107/s1600577519005423.
  • Schart-Morén, Nadine; Agrawal, Sumit K.; Ladak, Hanif M.; Li, Hao; Rask-Andersen, Helge et al. (2019). Effects of Various Trajectories on Tissue Preservation in Cochlear Implant Surgery. Ear and Hearing 40(2) , 393–400. 10.1097/aud.0000000000000624.
  • Shrestha, Pranay; Ouellette, David; Lee, Jongmin; Ge, Nan; Wong, Andrew Kai Cheung et al. (2019). Graded Microporous Layers for Enhanced Capillary‐Driven Liquid Water Removal in Polymer Electrolyte Membrane Fuel Cells. Advanced Materials Interfaces (6) , 1901157 (1-10). 10.1002/admi.201901157.
  • Soltan, Nikoo; Kawalilak, Chantal E.; Cooper, David M.; Kontulainen, Saija A.; Johnston, James D. et al. (2019). Cortical porosity assessment in the distal radius: A comparison of HR-pQCT measures with Synchrotron-Radiation micro-CT-based measures. Bone 120, 439-445. 10.1016/j.bone.2018.12.008.
  • Song, Ping; Natale, Giovanniantonio; Wang, Jingyi; Bond, Toby; Hejazi, Hossein et al. (2019). 2D and 3D Metal-Organic Framework at the Oil/Water Interface: A Case Study of Copper Benzenedicarboxylate. Advanced Materials Interfaces 6(2) , 1801139. 10.1002/admi.201801139.
  • Wong, A.K.C.; Ge, N.; Shrestha, P.; Liu, H.; Fahy, K. et al. (2019). Polytetrafluoroethylene content in standalone microporous layers: Tradeoff between membrane hydration and mass transport losses in polymer electrolyte membrane fuel cells. Applied Energy 240, 549-560. 10.1016/j.apenergy.2019.02.037.
  • Zhang, Honglin; Belev, George; Stewart, Rachel C.; Grinstaff, Mark W.; Snyder, Brian D. et al. (2019). Protocol development for synchrotron contrast-enhanced CT of human hip cartilage. Medical Engineering & Physics 73, 1-8. 10.1016/j.medengphy.2019.08.003.

2018 

  • Abedi, Ali; Cheng, He; Dalai, Ajay K. (2018). Effects of Natural Additives on the Properties of Sawdust Fuel Pellets. Energy & Fuels 32(2) , 1863-1873. 10.1021/acs.energyfuels.7b03663.
  • Agrawal, Sumit; Schart-Morén, Nadine; Liu, Wei; Ladak, Hanif M.; Rask-Andersen, Helge et al. (2018). The secondary spiral lamina and its relevance in cochlear implant surgery. Upsala Journal of Medical Sciences 123(1) , 9-18. 10.1080/03009734.2018.1443983.
  • Andronowski, Janna M.; Crowder, Christian; Soto Martinez, Miriam (2018). Recent advancements in the analysis of bone microstructure: new dimensions in forensic anthropology. Forensic Sciences Research 3(4) , 294-309. 10.1080/20961790.2018.1483294.
  • Banerjee, R.; Ge, N.; Han, C.; Lee, J.; George, M.G. et al. (2018). Identifying in operando changes in membrane hydration in polymer electrolyte membrane fuel cells using synchrotron X-ray radiography. International Journal of Hydrogen Energy 43(20) , 9757-9769. 10.1016/j.ijhydene.2018.03.224.
  • Bassey, B.; Samadi, N.; Panahifar, A.; Cooper, D.M.L.; Chapman, D. et al. (2018). Crossover artifact in X-ray focusing imaging systems: K-edge subtraction imaging. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators. Spectrometers. Detectors and Associated Equipment 910, 26-34. 10.1016/j.nima.2018.08.072.
  • Battrell, Logan; Zhu, Ning; Zhang, Lifeng; Anderson, Ryan (2018). Transient, spatially resolved desaturation of gas diffusion layers measured via synchrotron visualization. International Journal of Hydrogen Energy 43(24) , 11234-11243. 10.1016/j.ijhydene.2018.05.017.
  • Guillermic, R.-M.; Koksel, F.; Sun, X.; Hatcher, D.W.; Nickerson, M.T. et al. (2018). Bubbles in noodle dough: Characterization by X-ray microtomography. Food Research International 105, 548-555. 10.1016/j.foodres.2017.11.050.
  • Islam, Syed F.; Wysokinski, Tomasz W.; Belev, George; Sundara, Ramana V.; Whitehouse, Steve et al. (2018). Food suspensions study with SR microtomography. Chemical Engineering Science 175, 208-219. 10.1016/j.ces.2017.09.051.
  • Iyer, Janani S.; Zhu, Ning; Gasilov, Sergei; Ladak, Hanif M.; Agrawal, Sumit K. et al. (2018). Visualizing the 3D cytoarchitecture of the human cochlea in an intact temporal bone using synchrotron radiation phase contrast imaging. Biomedical Optics Express 9(8) , 3757-3767. 10.1364/boe.9.003757.
  • Jiang, Yunfei; Lahlali, Rachid; Karunakaran, Chithra; Warkentin, Thomas D.; Davis, Arthur R. et al. (2018). Pollen, ovules, and pollination in pea: Success, failure, and resilience in heat. Plant. Cell and Environment 42(1) , 354-372. 10.1111/pce.13427.
  • Liu, Hang; George, Michael G.; Ge, Nan; Muirhead, Daniel; Shrestha, Pranay et al. (2018). Microporous Layer Degradation in Polymer Electrolyte Membrane Fuel Cells. Journal of the Electrochemical Society 165(6) , F3271-F3280. 10.1149/2.0291806jes.
  • Mei, Xueshuang; Atturo, Francesca; Wadin, Karin; Larsson, Sune; Agrawal, Sumit et al. (2018). Human inner ear blood supply revisited: the Uppsala collection of temporal bone—an international resource of education and collaboration. Upsala Journal of Medical Sciences 123(3) , 131-142. 10.1080/03009734.2018.1492654.
  • Melli, S. Ali; Wahid, Khan A.; Babyn, Paul; Cooper, David M.L.; Hasan, Ahmed M. et al. (2018). A wavelet gradient sparsity based algorithm for reconstruction of reduced-view tomography datasets obtained with a monochromatic synchrotron-based X-ray source. Computerized Medical Imaging and Graphics 69, 69-81. 10.1016/j.compmedimag.2018.08.005.
  • Muirhead, Daniel; Banerjee, Rupak; George, Michael G.; Ge, Nan; Shrestha, Pranay et al. (2018). Liquid water saturation and oxygen transport resistance in polymer electrolyte membrane fuel cell gas diffusion layers. Electrochimica Acta 274, 250-265. 10.1016/j.electacta.2018.04.050.
  • Ning, Liqun; Sun, Haoying; Lelong, Tiphanie; Guilloteau, Romain; Zhu, Ning et al. (2018). 3D bioprinting of scaffolds with living Schwann cells for potential nerve tissue engineering applications. Biofabrication 10(3) , 035014. 10.1088/1758-5090/aacd30.
  • Pratt, Isaac V.; Cooper, David M. L. (2018). The effect of growth rate on the three-dimensional orientation of vascular canals in the cortical bone of broiler chickens. Journal of Anatomy 233(4) , 531-541. 10.1111/joa.12847.
  • Pratt, Isaac V.; Johnston, James D.; Walker, Ernie; Cooper, David M. L. (2018). Interpreting the three-dimensional orientation of vascular canals and cross-sectional geometry of cortical bone in birds and bats. Journal of Anatomy 232(6) , 931-942. 10.1111/joa.12803.
  • Rahimian, Paria; Battrell, Logan; Anderson, Ryan; Zhu, Ning; Johnson, Erick et al. (2018). Investigation of time dependent water droplet dynamics on porous fuel cell material via synchrotron based X-ray imaging technique. Experimental Thermal and Fluid Science 97, 237-245. 10.1016/j.expthermflusci.2018.04.021.
  • Schart-Morén, Nadine; Hallin, Karin; Agrawal, Sumit K.; Ladak, Hanif M.; Eriksson, Per-Olof et al. (2018). Peri-operative electrically evoked auditory brainstem response assessment of facial nerve/cochlea interaction at cochlear implantation. Cochlear Implants International 19(6) , 324-329. 10.1080/14670100.2018.1481179.
  • Shrestha, Pranay; Banerjee, Rupak; Lee, Jongmin; Ge, Nan; Muirhead, Daniel et al. (2018). Hydrophilic microporous layer coatings for polymer electrolyte membrane fuel cells operating without anode humidification. Journal of Power Sources 402, 468-482. 10.1016/j.jpowsour.2018.08.062.
  • Wysokinski, Tomasz W.; Renier, Michel; Suortti, Pekka; Belev, George; Rousset, Léo et al. (2018). High-power-load DCLM monochromator for a computed tomography program at BMIT at energies of 25–150 keV. Journal of Synchrotron Radiation 25(5) , 1548-1555. 10.1107/s1600577518008639.

2017 

  • Abedi, Ali; Dalai, Ajay K. (2017). Study on the quality of oat hull fuel pellets using bio-additives. Biomass and Bioenergy 106, 166-175. 10.1016/j.biombioe.2017.08.024.
  • Andronowski, Janna M.; Mundorff, Amy Z.; Pratt, Isaac V.; Davoren, Jon M.; Cooper, David M.L. et al. (2017). Evaluating differential nuclear DNA yield rates and osteocyte numbers among human bone tissue types: A synchrotron radiation micro-CT approach. Forensic Science International: Genetics 28, 211-218. 10.1016/j.fsigen.2017.03.002.
  • Andronowski, Janna M.; Pratt, Isaac V.; Cooper, David M. L. (2017). Occurrence of osteon banding in adult human cortical bone. American Journal of Physical Anthropology 164(3) , 635-642. 10.1002/ajpa.23297.
  • Aulakh, G K; Mann, A; Belev, G; Wiebe, S; Kuebler, W M et al. (2017). Multiple image x-radiography for functional lung imaging. Physics in Medicine and Biology 63(1) , 015009. 10.1088/1361-6560/aa9904.
  • BUKEJS, ANDRIS; ALEKSEEV, VITALII I.; COOPER, DAVID M.L.; KING, GAVIN A.; MCKELLAR, RYAN C. et al. (2017). Contributions to the palaeofauna of Ptinidae (Coleptera) known from Baltic amber. Zootaxa 4344(1) , 181-188. 10.11646/zootaxa.4344.1.12.
  • Banerjee, R.; Chevalier, S.; Liu, H.; Lee, J.; Yip, R. et al. (2017). A Comparison of Felt-Type and Paper-Type Gas Diffusion Layers for Polymer Electrolyte Membrane Fuel Cell Applications Using X-Ray Techniques. Journal of Electrochemical Energy Conversion and Storage 15(1) , 011002. 10.1115/1.4037766.
  • Banerjee, Rupak; Ge, Nan; Lee, Jongmin; George, Michael G.; Chevalier, Stéphane et al. (2017). Transient Liquid Water Distributions in Polymer Electrolyte Membrane Fuel Cell Gas Diffusion Layers Observed through In-Operando Synchrotron X-ray Radiography. Journal of the Electrochemical Society 164(2) , F154-F162. 10.1149/2.0991702jes.
  • Bawolin, N. K.; Chen, X. B. (2017). Remote Determination of Time-Dependent Stiffness of Surface-Degrading-Polymer Scaffolds Via Synchrotron-Based Imaging. Journal of Biomechanical Engineering 139(4) , 0410041-8. 10.1115/1.4036021.
  • Chevalier, S.; Ge, N.; Lee, J.; George, M.G.; Liu, H. et al. (2017). Novel electrospun gas diffusion layers for polymer electrolyte membrane fuel cells: Part II. In operando synchrotron imaging for microscale liquid water transport characterization. Journal of Power Sources 352, 281-290. 10.1016/j.jpowsour.2017.01.114.
  • Deman, P.; Tan, S.; Belev, G.; Samadi, N.; Martinson, M. et al. (2017). Respiratory-gated KES imaging of a rat model of acute lung injury at the Canadian Light Source. Journal of Synchrotron Radiation 24(3) , 679-685. 10.1107/s160057751700193x.
  • Elfarnawany, Mai; Rohani, Seyed Alireza; Ghomashchi, Soroush; Allen, Daniel G.; Zhu, Ning et al. (2017). Improved middle-ear soft-tissue visualization using synchrotron radiation phase-contrast imaging. Hearing Research 354, 1-8. 10.1016/j.heares.2017.08.001.
  • Ge, Nan; Chevalier, Stéphane; Lee, Jongmin; Yip, Ronnie; Banerjee, Rupak et al. (2017). Non-isothermal two-phase transport in a polymer electrolyte membrane fuel cell with crack-free microporous layers. International Journal of Heat and Mass Transfer 107, 418-431. 10.1016/j.ijheatmasstransfer.2016.11.045.
  • Ge, Nan; George, Michael G.; Lee, Jongmin; Muirhead, Daniel; Chevalier, Stéphane et al. (2017). Considering Photon Scattering and Harmonics for Synchrotron X-ray Radiographic Imaging of Polymer Electrolyte Membrane Fuel Cells. Journal of the Electrochemical Society 164(11) , E3215-E3224. 10.1149/2.0231711jes.
  • George, Michael G.; Liu, Hang; Muirhead, Daniel; Banerjee, Rupak; Ge, Nan et al. (2017). Accelerated Degradation of Polymer Electrolyte Membrane Fuel Cell Gas Diffusion Layers. Journal of the Electrochemical Society 164(7) , F714-F721. 10.1149/2.0091707jes.
  • Grochulski, Pawel; Fodje, Michel; Labiuk, Shaun; Wysokinski, Tomasz W.; Belev, George et al. (2017). Review of Canadian Light Source facilities for biological applications. Nuclear Instruments and Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 411, 17-21. 10.1016/j.nimb.2017.01.065.
  • Izadifar, Mohammad; Babyn, Paul; Chapman, Dean; Kelly, Michael E.; Chen, Xiongbiao et al. (2017). Potential of propagation-based synchrotron X-ray phase-contrast computed tomography for cardiac tissue engineering. Journal of Synchrotron Radiation 24(4) , 842-853. 10.1107/s1600577517006208.
  • Izadifar, Mohammad; Babyn, Paul; Kelly, Michael E.; Chapman, Dean; Chen, Xiongbiao et al. (2017). Bioprinting Pattern-Dependent Electrical/Mechanical Behavior of Cardiac Alginate Implants: Characterization and Ex Vivo Phase-Contrast Microtomography Assessment. Tissue Engineering - Part C: Methods 23(9) , 548-564. 10.1089/ten.tec.2017.0222.
  • Izadifar, Mohammad; Kelly, Michael E; Peeling, Lissa (2017). Synchrotron speckle-based x-ray phase-contrast imaging for mapping intra-aneurysmal blood flow without contrast agent. Biomedical Physics and Engineering Express 4(1) , 015011. 10.1088/2057-1976/aa8e0d.
  • Koch, Robert W.; Elfarnawany, Mai; Zhu, Ning; Ladak, Hanif M.; Agrawal, Sumit K. et al. (2017). Evaluation of Cochlear Duct Length Computations Using Synchrotron Radiation Phase-Contrast Imaging. Otology and Neurotology 38(6) , e92-e99. 10.1097/mao.0000000000001410.
  • Koksel, Filiz; Strybulevych, Anatoliy; Aritan, Serdar; Page, John H.; Scanlon, Martin G. et al. (2017). The use of synchrotron X-rays and ultrasonics for investigating the bubble size distribution and its evolution in bread dough. Journal of Cereal Science 78, 10-18. 10.1016/j.jcs.2017.06.022.
  • Lahondère, Chloé; Insausti, Teresita C; Paim, Rafaela MM; Luan, Xiaojie; Belev, George et al. (2017). Countercurrent heat exchange and thermoregulation during blood-feeding in kissing bugs. eLife 6, e26107. 10.7554/elife.26107.
  • Lee, J.; Banerjee, R.; George, M. G.; Muirhead, D.; Shrestha, P. et al. (2017). Multiwall Carbon Nanotube-Based Microporous Layers for Polymer Electrolyte Membrane Fuel Cells. Journal of the Electrochemical Society 164(12) , F1149-F1157. 10.1149/2.0861712jes.
  • Lee, J.; Chevalier, S.; Banerjee, R.; Antonacci, P.; Ge, N. et al. (2017). Investigating the effects of gas diffusion layer substrate thickness on polymer electrolyte membrane fuel cell performance via synchrotron X-ray radiography. Electrochimica Acta 236, 161-170. 10.1016/j.electacta.2017.03.162.
  • Liu, Hang; George, Michael G.; Banerjee, Rupak; Ge, Nan; Lee, Jongmin et al. (2017). Accelerated Degradation of Polymer Electrolyte Membrane Fuel Cell Gas Diffusion Layers. Journal of the Electrochemical Society 164(7) , F704-F713. 10.1149/2.0081707jes.
  • Luan, Xiaojie; Belev, George; Tam, Julian S.; Jagadeeshan, Santosh; Hassan, Noman et al. (2017). Cystic fibrosis swine fail to secrete airway surface liquid in response to inhalation of pathogens. Nature Communications 8(1) , 786. 10.1038/s41467-017-00835-7.
  • Martinson, Mercedes; Samadi, Nazanin; Shi, Xianbo; Liu, Zunping; Assoufid, Lahsen et al. (2017). Characterization of a bent Laue double-crystal beam-expanding monochromator. Journal of Synchrotron Radiation 24(6) , 1146-1151. 10.1107/s1600577517014059.
  • Muirhead, Daniel; Banerjee, Rupak; Lee, Jongmin; George, Michael G.; Ge, Nan et al. (2017). Simultaneous characterization of oxygen transport resistance and spatially resolved liquid water saturation at high-current density of polymer electrolyte membrane fuel cells with varied cathode relative humidity. International Journal of Hydrogen Energy 42(49) , 29472-29483. 10.1016/j.ijhydene.2017.10.031.
  • Olubamiji, Adeola D.; Zhu, Ning; Chang, Tuanjie; Nwankwo, Chijioke K.; Izadifar, Zohreh et al. (2017). Traditional Invasive and Synchrotron-Based Noninvasive Assessments of Three-Dimensional-Printed Hybrid Cartilage Constructs In Situ. Tissue Engineering - Part C: Methods 23(3) , 156-168. 10.1089/ten.tec.2016.0368.
  • Pratt, Isaac Vorster; Cooper, David Michael Lane (2017). A method for measuring the three-dimensional orientation of cortical canals with implications for comparative analysis of bone microstructure in vertebrates. Micron 92, 32-38. 10.1016/j.micron.2016.10.006.
  • Simovich, Tomer; Ritchie, Cameron; Belev, George; Cooper, David M. L.; Lamb, Robert N. et al. (2017). Superhydrophobicity from the Inside. Langmuir 33(49) , 13990-13995. 10.1021/acs.langmuir.7b01350.

2016 

  • Antonacci, P.; Chevalier, S.; Lee, J.; Ge, N.; Hinebaugh, J. et al. (2016). Balancing mass transport resistance and membrane resistance when tailoring microporous layer thickness for polymer electrolyte membrane fuel cells operating at high current densities. Electrochimica Acta 188, 888-897. 10.1016/j.electacta.2015.11.115.
  • Basnayaka, Upekha; Chapman, Dean (2016). Synchrotron Imaging of Ovaries Ex Vivo. Journal of Fertilization In Vitro - IVF-Worldwide Reproductive Medicine Genetics & Stem Cell Biology 04(01) , 169. 10.4172/2375-4508.1000169.
  • Bassey, B; Martinson, M; Samadi, N; Belev, G; Karanfil, C et al. (2016). Multiple energy synchrotron biomedical imaging system. Physics in Medicine and Biology 61(23) , 8180-8198. 10.1088/0031-9155/61/23/8180.
  • Bawolin, Nahshon; Chen, Xiongbaio (2016). Synchrotron-Based in Situ Characterization of the Scaffold Mass Loss from Erosion Degradation. Journal of Functional Biomaterials 7(3) , 17. 10.3390/jfb7030017.
  • Bond, Toby; Zhou, Jigang; Cutler, Jeffrey (2016). Electrode Stack Geometry Changes during Gas Evolution in Pouch-Cell-Type Lithium Ion Batteries. Journal of the Electrochemical Society 164(1) , A6158-A6162. 10.1149/2.0241701jes.
  • Chevalier, S.; Ge, N.; George, M. G.; Lee, J.; Banerjee, R. et al. (2016). Synchrotron X-ray Radiography as a Highly Precise and Accurate Method for Measuring the Spatial Distribution of Liquid Water in Operating Polymer Electrolyte Membrane Fuel Cells. Journal of the Electrochemical Society 164(2) , F107-F114. 10.1149/2.0041702jes.
  • Chevalier, S.; Lee, J.; Ge, N.; Yip, R.; Antonacci, P. et al. (2016). In operando measurements of liquid water saturation distributions and effective diffusivities of polymer electrolyte membrane fuel cell gas diffusion layers. Electrochimica Acta 210, 792-803. 10.1016/j.electacta.2016.05.180.
  • Cooper, D. M. L.; Kawalilak, C. E.; Harrison, K.; Johnston, B. D.; Johnston, J. D. et al. (2016). Cortical Bone Porosity: What Is It, Why Is It Important, and How Can We Detect It?. Current Osteoporosis Reports 14(5) , 187-198. 10.1007/s11914-016-0319-y.
  • ELFARNAWANY, M.; ALAM, S. RIYAHI; ROHANI, S.A.; ZHU, N.; AGRAWAL, S.K. et al. (2016). Micro-CT versus synchrotron radiation phase contrast imaging of human cochlea. Journal of Microscopy 265(3) , 349-357. 10.1111/jmi.12507.
  • Ge, Nan; Chevalier, Stéphane; Hinebaugh, James; Yip, Ronnie; Lee, Jongmin et al. (2016). Calibrating the X-ray attenuation of liquid water and correcting sample movement artefacts duringin operandosynchrotron X-ray radiographic imaging of polymer electrolyte membrane fuel cells. Journal of Synchrotron Radiation 23(2) , 590-599. 10.1107/s1600577515023899.
  • Hedayat, Assem; Nagy, Nicole; Packota, Garnet; Monteith, Judy; Allen, Darcy et al. (2016). Synchrotron-radiation-based X-ray micro-computed tomography reveals dental bur debris under dental composite restorations. Journal of Synchrotron Radiation 23(3) , 777-782. 10.1107/s1600577516002198.
  • Izadifar, Zohreh; Honaramooz, Ali; Wiebe, Sheldon; Belev, George; Chen, Xiongbiao et al. (2016). Low-dose phase-based X-ray imaging techniques for in situ soft tissue engineering assessments. Biomaterials 82, 151-167. 10.1016/j.biomaterials.2015.11.044.
  • Izadifar, Zohreh; Honaramooz, Ali; Wiebe, Sheldon; Belev, George; Chen, Xiongbiao et al. (2016). Data of low-dose phase-based X-ray imaging for in situ soft tissue engineering assessments. Data in Brief 6, 644-651. 10.1016/j.dib.2015.12.054.
  • Koksel, Filiz; Aritan, Serdar; Strybulevych, Anatoliy; Page, John H.; Scanlon, Martin G. et al. (2016). The bubble size distribution and its evolution in non-yeasted wheat flour doughs investigated by synchrotron X-ray microtomography. Food Research International 80, 12-18. 10.1016/j.foodres.2015.12.005.
  • Martinson, Mercedes; Chapman, Dean (2016). Measuring the criticality of the `magic condition' for a beam-expanding monochromator. Journal of Synchrotron Radiation 23(6) , 1498-1500. 10.1107/s1600577516012650.
  • Melli, S. Ali; Wahid, Khan A.; Babyn, Paul; Cooper, David M. L.; Gopi, Varun P. et al. (2016). A sparsity-based iterative algorithm for reconstruction of micro-CT images from highly undersampled projection datasets obtained with a synchrotron X-ray source. Review of Scientific Instruments 87(12) , 123701. 10.1063/1.4968198.
  • Melli, Seyed Ali; Wahid, Khan A.; Babyn, Paul; Montgomery, James; Snead, Elisabeth et al. (2016). A compressed sensing based reconstruction algorithm for synchrotron source propagation-based X-ray phase contrast computed tomography. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators. Spectrometers. Detectors and Associated Equipment 806, 307-317. 10.1016/j.nima.2015.10.013.
  • Montgomery, James E.; Wesolowski, Michal J.; Wolkowski, Bailey; Chibbar, Rajni; Snead, Elisabeth C. R. et al. (2016). Demonstration of synchrotron x-ray phase contrast imaging computed tomography of infiltrative transitional cell carcinoma of the prostatic urethra in a dog. Journal of Medical Imaging 3(1) , 015504. 10.1117/1.jmi.3.1.015504.
  • Niestroj, M; Bewer, B; Mousseau, D D; Chapman, D; Chen, J et al. (2016). A monochromatic x-ray irradiation system forin vitrostudies at synchrotron beamlines. Biomedical Physics and Engineering Express 2(5) , 055001. 10.1088/2057-1976/2/5/055001.
  • Olubamiji, Adeola D.; Izadifar, Zohreh; Zhu, Ning; Chang, Tuanjie; Chen, Xiongbiao et al. (2016). Using synchrotron radiation inline phase-contrast imaging computed tomography to visualize three-dimensional printed hybrid constructs for cartilage tissue engineering. Journal of Synchrotron Radiation 23(3) , 802-812. 10.1107/s1600577516002344.
  • Panahifar, Arash; Samadi, Nazanin; Swanston, Treena M.; Chapman, L. Dean; Cooper, David M.L. et al. (2016). Spectral K-edge subtraction imaging of experimental non-radioactive barium uptake in bone. Physica Medica 32(12) , 1765-1770. 10.1016/j.ejmp.2016.07.619.
  • Panahifar, Arash; Swanston, Treena M; Jake Pushie, M; Belev, George; Chapman, Dean et al. (2016). Three-dimensional labeling of newly formed bone using synchrotron radiation barium K-edge subtraction imaging. Physics in Medicine and Biology 61(13) , 5077-5088. 10.1088/0031-9155/61/13/5077.
  • Wysokinski, T.W.; Ianowski, J.P.; Luan, X.; Belev, G.; Miller, D. et al. (2016). BMIT facility at the Canadian Light Source: Advances in X-ray phase-sensitive imaging. Physica Medica 32(12) , 1753-1758. 10.1016/j.ejmp.2016.07.090.
  • You, Fu; Wu, Xia; Zhu, Ning; Lei, Ming; Eames, B. Frank et al. (2016). 3D Printing of Porous Cell-Laden Hydrogel Constructs for Potential Applications in Cartilage Tissue Engineering. ACS Biomaterials Science and Engineering 2(7) , 1200-1210. 10.1021/acsbiomaterials.6b00258.

2015 

  • Antonacci, P.; Chevalier, S.; Lee, J.; Yip, R.; Ge, N. et al. (2015). Feasibility of combining electrochemical impedance spectroscopy and synchrotron X-ray radiography for determining the influence of liquid water on polymer electrolyte membrane fuel cell performance. International Journal of Hydrogen Energy 40(46) , 16494-16502. 10.1016/j.ijhydene.2015.10.008.
  • Bawolin, Nahshon K.; Dolovich, Allan T.; Chen, Daniel X. B.; Zhang, Chris W. J. (2015). Characterization of Mechanical Properties of Tissue Scaffolds by Phase Contrast Imaging and Finite Element Modeling. Journal of Biomechanical Engineering 137(8) , 081004-081004-8. 10.1115/1.4030409.
  • Chevalier, S.; Ge, N.; Lee, J.; Antonacci, P.; Yip, R. et al. (2015). In situ analysis of voltage degradation in a polymer electrolyte membrane fuel cell with a dead-ended anode. Electrochemistry Communications 59, 16-19. 10.1016/j.elecom.2015.06.009.
  • Gagnon, Kenneth B.; Caine, Sally; Samadi, Nazanin; Martinson, Mercedes; van der Loop, Melanie et al. (2015). Design of a mouse restraint for synchrotron-based computed tomography imaging. Journal of Synchrotron Radiation 22(5) , 1297-1300. 10.1107/s160057751501036x.
  • Harrison, Kimberly D.; Cooper, David M. L. (2015). Modalities for Visualization of Cortical Bone Remodeling: The Past, Present, and Future. Frontiers in Endocrinology 6, 84. 10.3389/fendo.2015.00122.
  • Hinebaugh, J.; Lee, J.; Mascarenhas, C.; Bazylak, A. (2015). Quantifying Percolation Events in PEM Fuel Cell Using Synchrotron Radiography. Electrochimica Acta 184, 417-426. 10.1016/j.electacta.2015.09.058.
  • Izadifar, Zahra; Belev, George; Babyn, Paul; Chapman, Dean (2015). Application of analyzer based X-ray imaging technique for detection of ultrasound induced cavitation bubbles from a physical therapy unit. BioMedical Engineering Online 14(1) , 91. 10.1186/s12938-015-0085-6.
  • Jorgenson, Britta L.; Buie, Helen R.; McErlain, David D.; Sandino, Clara; Boyd, Steven K. et al. (2015). A comparison of methods for in vivo assessment of cortical porosity in the human appendicular skeleton. Bone 73, 167-175. 10.1016/j.bone.2014.11.023.
  • Karunakaran, Chithra; Lahlali, Rachid; Zhu, Ning; Webb, Adam M.; Schmidt, Marina et al. (2015). Factors influencing real time internal structural visualization and dynamic process monitoring in plants using synchrotron-based phase contrast X-ray imaging. Scientific Reports 5(1) , 12119. 10.1038/srep12119.
  • Lahlali, Rachid; Karunakaran, Chithra; Wang, Lipu; Willick, Ian; Schmidt, Marina et al. (2015). Synchrotron based phase contrast X-ray imaging combined with FTIR spectroscopy reveals structural and biomolecular differences in spikelets play a significant role in resistance to Fusarium in wheat. BMC Plant Biology 15(1) , 24. 10.1186/s12870-014-0357-5.
  • Lee, J.; Yip, R.; Antonacci, P.; Ge, N.; Kotaka, T. et al. (2015). Synchrotron Investigation of Microporous Layer Thickness on Liquid Water Distribution in a PEM Fuel Cell. Journal of the Electrochemical Society 162(7) , F669-F676. 10.1149/2.0221507jes.
  • Martinson, Mercedes; Samadi, Nazanin; Bassey, Bassey; Gomez, Ariel; Chapman, Dean et al. (2015). Phase-preserving beam expander for biomedical X-ray imaging. Journal of Synchrotron Radiation 22(3) , 801-806. 10.1107/s1600577515004695.
  • Mitkova, Maria; Wolf, Kasandra; Belev, George; Ailavajhala, Mahesh; Tenne, Dmitri A. et al. (2015). X-ray radiation induced effects in selected chalcogenide glasses and CBRAM devices based on them. Physica Status Solidi (B): Basic Research 253(6) , 1060-1068. 10.1002/pssb.201552562.
  • Panahifar, Arash; Cooper, David M.L.; Doschak, Michael R. (2015). 3‐D localization of non‐radioactive strontium in osteoarthritic bone: Role in the dynamic labeling of bone pathological changes. Journal of Orthopaedic Research 33(11) , 1655 -1662. 10.1002/jor.22937.
  • Rhoades; Glendon W; Belev; George; Chapman et al. (2015). Diffraction-Enhanced Computed Tomographic Imaging of Growing Piglet Joints by Using a Synchrotron Light Source. Comparative Medicine 65(4) , 342-347.
  • Samadi, Nazanin; Bassey, Bassey; Martinson, Mercedes; Belev, George; Dallin, Les et al. (2015). A phase-space beam position monitor for synchrotron radiation. Journal of Synchrotron Radiation 22(4) , 946-955. 10.1107/s1600577515007390.
  • Wiebe, Sheldon; Samadi, Nazanin; Belev, George; Martinson, Mercedes; Bassey, Bassey et al. (2015). Small and Ultra-Small Angle X-Ray Scattering Contrast Obtained With a Synchrotron-Based Shack–Hartmann Imaging System. IEEE Transactions on Nuclear Science 62(5) , 2031-2035. 10.1109/tns.2015.2470555.
  • Wiebe, Sheldon; Wysokinski, Tomasz W.; Belev, George; Miller, Denise; Webb, Adam et al. (2015). Biomedical Imaging Using Synchrotron Radiation: Experience at the Biomedical Imaging and Therapy (BMIT) Facility at the Canadian Light Source. Synchrotron Radiation News 28(5) , 16-23. 10.1080/08940886.2015.1080065.
  • Wolkowski, Bailey; Snead, Elisabeth; Wesolowski, Michal; Singh, Jaswant; Pettitt, Murray et al. (2015). Assessment of freeware programs for the reconstruction of tomography datasets obtained with a monochromatic synchrotron-based X-ray source. Journal of Synchrotron Radiation 22(4) , 1130-1138. 10.1107/s1600577515008437.
  • Wysokinski, Tomasz W.; Chapman, Dean; Adams, Gregg; Renier, Michel; Suortti, Pekka et al. (2015). Beamlines of the biomedical imaging and therapy facility at the Canadian light source – part 3. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators. Spectrometers. Detectors and Associated Equipment 775, 1-4. 10.1016/j.nima.2014.11.088.

2014 

  • Anderson, Danielle L.; Mirzayans, Razmik; Andrais, Bonnie; Siegbahn, E. Albert; Fallone, B. Gino et al. (2014). Spatial and temporal distribution of γH2AX fluorescence in human cell cultures following synchrotron-generated X-ray microbeams: lack of correlation between persistent γH2AX foci and apoptosis. Journal of Synchrotron Radiation 21(4) , 801-810. 10.1107/s1600577514011424.
  • Basnayaka, Upekha; Chapman, Dean; Adams, Gregg; Wysokinski, Tomasz; Belev, George et al. (2014). Diffraction-enhanced Synchrotron Imaging of Bovine Ovaries Ex Vivo. Journal of Medical Imaging and Radiation Sciences 45(3) , 307-315. 10.1016/j.jmir.2014.01.004.
  • Bassey, Bassey; Abueidda, Abdallah; Cubbon, Grant; Street, Darin; Sabbir Ahmed, Asm et al. (2014). Supplemental shielding of BMIT SOE-1 at the Canadian Light Source. Radiation Physics and Chemistry 100, 8-12. 10.1016/j.radphyschem.2014.02.023.
  • Izadifar, Zahra; Belev, George; Izadifar, Mohammad; Izadifar, Zohreh; Chapman, Dean et al. (2014). Visualization of ultrasound induced cavitation bubbles using the synchrotron x-ray Analyzer Based Imaging technique. Physics in Medicine and Biology 59(23) , 7541-7555. 10.1088/0031-9155/59/23/7541.
  • Izadifar, Zohreh; Chapman, Leroy Dean; Chen, Xiongbiao (2014). Computed Tomography Diffraction-Enhanced Imaging forIn SituVisualization of Tissue Scaffolds Implanted in Cartilage. Tissue Engineering - Part C: Methods 20(2) , 140-148. 10.1089/ten.tec.2013.0138.
  • Lieverse, A.R.; Pratt, I.V.; Schulting, R.J.; Cooper, D.M.L.; Bazaliiskii, V.I. et al. (2014). Point taken: An unusual case of incisor agenesis and mandibular trauma in Early Bronze Age Siberia. International Journal of Paleopathology 6, 53-59. 10.1016/j.ijpp.2014.04.004.
  • Luan, X.; Campanucci, V. A.; Nair, M.; Yilmaz, O.; Belev, G. et al. (2014). Pseudomonas aeruginosa triggers CFTR-mediated airway surface liquid secretion in swine trachea. Proceedings of the National Academy of Sciences of the United States of America 111(35) , 12930-12935. 10.1073/pnas.1406414111.
  • Martinson, Mercedes; Samadi, Nazanin; Belev, George; Bassey, Bassey; Lewis, Rob et al. (2014). Development of a bent Laue beam-expanding double-crystal monochromator for biomedical X-ray imaging. Journal of Synchrotron Radiation 21(3) , 479-483. 10.1107/s1600577514003014.
  • Morrell, B.; Okada, G.; Vahedi, S.; Koughia, C.; Edgar, A. et al. (2014). Optically erasable samarium-doped fluorophosphate glasses for high-dose measurements in microbeam radiation therapy. Journal of Applied Physics 115(6) , 063107-1 - 063107-8. 10.1063/1.4864424.
  • Okada, Go; Ueda, Jumpei; Tanabe, Setsuhisa; Belev, George; Wysokinski, Tomasz et al. (2014). Samarium-Doped Oxyfluoride Glass-Ceramic as a New Fast Erasable Dosimetric Detector Material for Microbeam Radiation Cancer Therapy Applications at the Canadian Synchrotron. Journal of the American Ceramic Society 97(7) , 2147-2153. 10.1111/jace.12938.
  • Pratt, I V; Belev, G; Zhu, N; Chapman, L D; Cooper, D M L et al. (2014). In vivoimaging of rat cortical bone porosity by synchrotron phase contrast micro computed tomography. Physics in Medicine and Biology 60(1) , 211-232. 10.1088/0031-9155/60/1/211.
  • Tonchev, D.; Kostova, I.; Okada, G.; Pashova, T.; Belev, G. et al. (2014). Samarium Doped Borophosphate Glasses and Glass-Ceramics for X-ray Radiation Sensing. NATO Science for Peace and Security Series A: Chemistry and Biology , 347-358. 10.1007/978-94-017-9697-2_36.
  • Zhu, Y; Samadi, N; Martinson, M; Bassey, B; Wei, Z et al. (2014). SpectralK-edge subtraction imaging. Physics in Medicine and Biology 59(10) , 2485-2503. 10.1088/0031-9155/59/10/2485.

2013 

  • Anderson, D; Andrais, B; Mirzayans, R; Siegbahn, E A; Fallone, B G et al. (2013). Comparison of two methods for measuring γ-H2AX nuclear fluorescence as a marker of DNA damage in cultured human cells: applications for microbeam radiation therapy. Journal of Instrumentation 8(06) , C06008-C06008. 10.1088/1748-0221/8/06/c06008.
  • Asai, J.; Hirayama, H. (2013). Dose estimates when electrons strike a copper absorber during injection at the Canadian Light Source. Radiation Measurements 51-52, 92-98. 10.1016/j.radmeas.2013.02.010.
  • Lee, J.; Hinebaugh, J.; Bazylak, A. (2013). Synchrotron X-ray radiographic investigations of liquid water transport behavior in a PEMFC with MPL-coated GDLs. Journal of Power Sources 227, 123-130. 10.1016/j.jpowsour.2012.11.006.
  • Martin, Vincent; Okada, Go; Tonchev, Dancho; Belev, George; Wysokinski, Tomasz et al. (2013). Samarium-doped oxyfluoride borophosphate glasses for x-ray dosimetry in Microbeam Radiation Therapy. Journal of Non-Crystalline Solids 377, 137-141. 10.1016/j.jnoncrysol.2012.12.015.
  • Midgley, S M (2013). Feasibility study for DEXA using synchrotron CT at 20–35 keV. Physics in Medicine and Biology 58(4) , 1185-1205. 10.1088/0031-9155/58/4/1185.
  • Okada, Go; Vahedi, Shahrzad; Morrell, Brian; Koughia, Cyril; Belev, George et al. (2013). Examination of the dynamic range of Sm-doped glasses for high-dose and high-resolution dosimetric applications in microbeam radiation therapy at the Canadian synchrotron. Optical Materials 35(11) , 1976-1980. 10.1016/j.optmat.2012.10.049.
  • P. Gopi, Varun; Palanisamy, P.; A. Wahid, Khan; Babyn, Paul; Cooper, David et al. (2013). Micro-CT image reconstruction based on alternating direction augmented Lagrangian method and total variation. Computerized Medical Imaging and Graphics 37(7-8) , 419-429. 10.1016/j.compmedimag.2013.08.006.
  • Raj, Muhammad T.; Prusinkiewicz, Martin; Cooper, David M.L.; George, Belev; Webb, M. Adam et al. (2013). Technique: Imaging Earliest Tooth Development in 3D Using a Silver-Based Tissue Contrast Agent. Anatomical Record 297(2) , 222-233. 10.1002/ar.22845.
  • Webb, M A; Belev, G; Wysokinski, T W; Chapman, D (2013). Diffraction enhanced imaging computed tomography (DEI-CT) at the BMIT facility at the Canadian Light Source. Journal of Instrumentation 8(08) , C08002-1 - C08002-5. 10.1088/1748-0221/8/08/c08002.
  • Wei, Zhouping; Wiebe, Sheldon; Chapman, Dean (2013). Ring artifacts removal from synchrotron CT image slices. Journal of Instrumentation 8(06) , C06006-1 - C06006-12. 10.1088/1748-0221/8/06/c06006.
  • Wiebe, S; Rhoades, G; Wei, Z; Rosenberg, A; Belev, G et al. (2013). Understanding refraction contrast using a comparison of absorption and refraction computed tomographic techniques. Journal of Instrumentation 8(05) , C05004-C05004. 10.1088/1748-0221/8/05/c05004.
  • Zhu, Zangen; Wahid, Khan; Babyn, Paul; Cooper, David; Pratt, Isaac et al. (2013). Improved Compressed Sensing-Based Algorithm for Sparse-View CT Image Reconstruction. Computational and Mathematical Methods in Medicine 2013, 1-15. 10.1155/2013/185750.

2012 

  • Anderson, Danielle; Siegbahn, E Albert; Fallone, B Gino; Serduc, Raphael; Warkentin, Brad et al. (2012). Evaluation of dose-volume metrics for microbeam radiation therapy dose distributions in head phantoms of various sizes using Monte Carlo simulations. Physics in Medicine and Biology 57(10) , 3223-3248. 10.1088/0031-9155/57/10/3223.
  • Britz, Hayley M.; Carter, Yasmin; Jokihaara, Jarkko; Leppänen, Olli V.; Järvinen, Teppo L.N. et al. (2012). Prolonged unloading in growing rats reduces cortical osteocyte lacunar density and volume in the distal tibia. Bone 51(5) , 913-919. 10.1016/j.bone.2012.08.112.
  • Cooper, D M L; Chapman, L D; Carter, Y; Wu, Y; Panahifar, A et al. (2012). Three dimensional mapping of strontium in bone by dual energy K-edge subtraction imaging. Physics in Medicine and Biology 57(18) , 5777-5786. 10.1088/0031-9155/57/18/5777.
  • Hinebaugh, J.; Challa, P. R.; Bazylak, A. (2012). Accounting for low-frequency synchrotron X-ray beam position fluctuations for dynamic visualizations. Journal of Synchrotron Radiation 19(6) , 994-1000. 10.1107/s0909049512039118.
  • Hinebaugh, J.; Lee, J.; Bazylak, A. (2012). Visualizing Liquid Water Evolution in a PEM Fuel Cell Using Synchrotron X-ray Radiography. Journal of the Electrochemical Society 159(12) , F826-F830. 10.1149/2.054212jes.
  • Landheer, Karl; Johns, Paul C. (2012). Synchrotron-based coherent scatter x-ray projection imaging using an array of monoenergetic pencil beams. Review of Scientific Instruments 83(9) , 095114. 10.1063/1.4754124.
  • M. Hunter, David; Belev, George; Kasap, Safa; J. Yaffe, Martin (2012). Measured and calculated K-fluorescence effects on the MTF of an amorphous-selenium based CCD x-ray detector. Medical Physics 39(2) , 608-622. 10.1118/1.3673957.
  • Vahedi, Shahrzad; Okada, Go; Morrell, Brian; Muzar, Edward; Koughia, Cyril et al. (2012). X-ray induced Sm3+ to Sm2+ conversion in fluorophosphate and fluoroaluminate glasses for the monitoring of high-doses in microbeam radiation therapy. Journal of Applied Physics 112(7) , 073108. 10.1063/1.4754564.

2011 

  • Asai, J.; Hirayama, H. (2011). Dose estimates for an insertion device beamline with a tapered absorber at the Canadian Light Source. Radiation Measurements 46(4) , 418-424. 10.1016/j.radmeas.2011.02.021.
  • Asai, Juhachi; Wysokinski, Tomasz W.; Chapman, Dean; Mullin, Curtis (2011). Radiation shielding study against gas bremsstrahlung for the BMIT POE3 at the Canadian light source. Radiation Physics and Chemistry 80(6) , 716-722. 10.1016/j.radphyschem.2011.02.026.
  • Belev, George; Okada, Go; Tonchev, Dancho; Koughia, Cyril; Varoy, Chris et al. (2011). Valency conversion of samarium ions under high dose synchrotron generated X-ray radiation. Physica Status Solidi (C) Current Topics in Solid State Physics 8(9) , 2822-2825. 10.1002/pssc.201084103.
  • Belev, George; Wysokinski, Tomasz W.; Chapman, Dean; Mullin, Curtis; McKibben, Mike et al. (2011). Set of measurements for alignment of beamline components. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators. Spectrometers. Detectors and Associated Equipment 649(1) , 225-227. 10.1016/j.nima.2010.11.084.
  • Bewer, Brian (2011). An electron density measurement using an analyzer based imaging system. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators. Spectrometers. Detectors and Associated Equipment 646(1) , 197-199. 10.1016/j.nima.2011.05.005.
  • Cooper, David M. L.; Bewer, Brian; Wiebe, Sheldon; Belev, George; Wysokinski, Tomasz et al. (2011). Preliminary Bone Imaging on 05B1-1 Beamline at the Canadian Light Source: Exploration of Diffraction Enhanced Imaging. Synchrotron Radiation News 24(2) , 13-18. 10.1080/08940886.2011.567163.
  • Cooper, David M.L.; Bewer, Brian; Wiebe, Sheldon; Wysokinski, Tomasz W.; Chapman, Dean et al. (2011). Diffraction Enhanced X-ray Imaging of the Distal Radius: A Novel Approach for Visualization of Trabecular Bone Architecture. Canadian Association of Radiologists Journal 62(4) , 251-255. 10.1016/j.carj.2010.04.015.
  • Okada, Go; Morrell, Brian; Koughia, Cyril; Edgar, Andy; Varoy, Chris et al. (2011). Spatially resolved measurement of high doses in microbeam radiation therapy using samarium doped fluorophosphate glasses. Applied Physics Letters 99(12) , 121105. 10.1063/1.3633102.
  • Olkowski, A. A.; Laarveld, B.; Wojnarowicz, C.; Chirino-Trejo, M.; Chapman, D. et al. (2011). Biochemical and physiological weaknesses associated with the pathogenesis of femoral bone degeneration in broiler chickens. Avian Pathology 40(6) , 639-650. 10.1080/03079457.2011.626017.
  • Zhu, Ning; Chapman, Dean; Cooper, David; Schreyer, David J.; Chen, Xiongbiao et al. (2011). X-Ray Diffraction Enhanced Imaging as a Novel Method to Visualize Low-Density Scaffolds in Soft Tissue Engineering. Tissue Engineering - Part C: Methods 17(11) , 1071-1080. 10.1089/ten.tec.2011.0102.

2010 

  • Bewer, Brian; Chapman, Dean (2010). Development of an x-ray prism for analyzer based imaging systems. Review of Scientific Instruments 81(8) , 085108. 10.1063/1.3478018.

2008 

  • Asai, Juhachi; Wysokinski, Tomasz W.; Smith, Sheldon; Chapman, Dean (2008). Radiological considerations for POE-1 photon shutters, collimators and beam stops of the Biomedical Imaging and Therapy beamline at the Canadian Light Source. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators. Spectrometers. Detectors and Associated Equipment 585(1-2) , 1-11. 10.1016/j.nima.2007.10.049.

2007 

  • Wysokinski, Tomasz W.; Chapman, Dean; Adams, Gregg; Renier, Michel; Suortti, Pekka et al. (2007). Beamlines of the biomedical imaging and therapy facility at the Canadian light source—Part 1. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators. Spectrometers. Detectors and Associated Equipment 582(1) , 73-76. 10.1016/j.nima.2007.08.087.